CHAPTER
3-1
Cisco 4x InfiniBand Switch Module for IBM BladeCenter User Guide
78-17838-01
3
Specifications
This chapter details the Server Switch Module specifications.
Electrical Requirements
Table 3-1 DC Supply Requirements
Note External port powered devices are limited to 21 watts total.
Environmental Requirements
Table 3-2 Environmental Requirements
Area Requirement
DC Supply Voltage 12.2 Volts nominal
DC Supply Current 6.0 Amps maximum
DC Supply Power without External Port Powered Devices 39 watts maximum
DC Supply Power with External Port Powered Devices 60 watts maximum
Area Requirement
Module Operating Temperature 0 to +60 degrees C (module inlet)
Forced Air Cooling: Rate 6.5 CFM minimum
Module Non-Operating Temperature -40 to +70 degrees C
Operating Altitude 0 to 2133 meters
Non-Operating Altitude 0 to 11,000 meters
Operating Humidity 5% to 85% non-condensing
Non-Operating Humidity 5% to 95% non-condensing
Operational Shock 3.5G for 3 mSec.